Bed Not Heating
I have the standard Vcore 3.1 300 kit with Octopus v1.1. When doing the confirmataion settings my bed will not heat up. I get no LED light on the relay. I do have AC going into the "Bed Power" terminal. I get no Power coming out of "Bed Out" terminal. It is the correct heating pad for my country as well. I am fairly sure my wiring is correct too.
12 Replies
please post a picture of your wiring
ratty-blush•2y ago
Hopefully you can see this.
well, your bed wires (in white - from the bed heating pad) are incorrect. Both of them do not get attached to the SSR
ratty-blush•2y ago
I diagram didnt show them so I was unsure about that. Where do they go?
The* diagram
checkout the diagram in the pinned messages in #general-electronics
ratty-blush•2y ago
I was not able to find what I need,
ratty-blush•2y ago
So you are saying that I need to like rewire my entire mains for the bed heater including using different switchs and grounds?
no idea, you haven't shown a picture of all that. But I am telling you have it currently wrong with the SSR
ratty-blush•2y ago
Okay thanks for the help
one AC MAIN goes straight to either wht heater bed wire. One AC MAIN wire goes to SSR. Other terminal of SSR goe to other heater WHT wire
The SSR is bascially your SWITCH to connect AC to the heater pad. it ids NOT the SOURCE of your AC power. The two little leads are your finger on the switch.
ratty-blush•2y ago
That fixed it. Thank you for the help.