Octopus Max Ez SuperPinda Probe Always Triggered

Probe has a red led on constantly. The led turns off when placing metal near the probe.

Tried a variety of other settings however the probe is either in a constant triggered or open state in Ratos > Machine section. It never changes states even when the probe led changes state when putting metal next to it.

Tripple checked the wiring everything looks good. Jumper is on the 5v pins. Its on the right socket per the wiring guide and labels on the board.

Any help is greatly appreciated.

#############################################################################################################

HOMING

Pick your probe and endstops

#############################################################################################################

BL Touch

#[include RatOS/z-probe/bltouch.cfg]

Inductive/Capacitive probe

[include RatOS/z-probe/superpinda.cfg]



Inductive probe configuration

[probe]
z_offset: 0.0 # Adjust this to fit your setup
pin: ^probe_pin # For NPN NC probes such as the Super Pinda / Vinda / SupCR / Decoprobe probes.
#pin: ^!probe_pin # NPN NO (refer to the specs on your probe)
#pin: probe_pin # PNP NO (refer to the specs on your probe)
#pin: !probe_pin # PNP NC (refer to the specs on your probe)
2023-12-01_23-35-25.jpg
PXL_20231202_071411416.MP.jpg
printer.cfg13.43KB
Was this page helpful?