Abnormal probe offset detected

Can anyone help resolve this error? I am getting it when trying to start a print after bed leveling and initial heating on V-Core 3 500mm.
Error evaluating 'gcode_macro PRIME_BLOB:gcode': gcode.CommandError: Abnormal probe offset detected. Needed offset of -1.90875 is below the offset threshold of -1mm. Please verify the probe is over the bed when probing for priming. If it isn't, you should adjust you min/max bed_mesh settings so the probe is always over the print area.
Error evaluating 'gcode_macro PRIME_BLOB:gcode': gcode.CommandError: Abnormal probe offset detected. Needed offset of -1.90875 is below the offset threshold of -1mm. Please verify the probe is over the bed when probing for priming. If it isn't, you should adjust you min/max bed_mesh settings so the probe is always over the print area.
Solution:
I reran PROBE_CALIBRATE and it seemed to solve the issue
Jump to solution
1 Reply
Solution
Andrew
Andrew7d ago
I reran PROBE_CALIBRATE and it seemed to solve the issue

Did you find this page helpful?