RRC
multiple-amethyst

The circle is not standard

V-core3.1After the assembly is completed, the round hole printed after the belt calibration is non-standard and a bit elliptical. I need help,
No description
24 Replies
fascinating-indigo
fascinating-indigo3y ago
Check if belt tension is equal, not too low, and that the pulleys are not slipping on the motor shafts.. that's the usual causes for non-round circles
multiple-amethyst
multiple-amethystOP3y ago
Is there any standard for belt tightness, such as how much hz is the best for testing
adverse-sapphire
adverse-sapphire3y ago
No, we usually hook an accelerometer to it and run the belt tightness macro. You can then get the files off your machine and test. You're looking for about matching peak height no matter what their actual height is, and more or less in the same area. Err on the side of too loose because too tight will 100% make your motors stall. If that doesnt work, you'll need to re square your machine which is a whole deal. Failing all that there is an out of square calibration procedure you can use but you should try exhausting hardware fixes first.
multiple-amethyst
multiple-amethystOP3y ago
belt tightbedd maxro,Where can I find it,Have you used the tutorial
adverse-sapphire
adverse-sapphire3y ago
If you dont see the belt tightness macro you need to enable it in settings. And I don't know any tutorial for it unfortunately
multiple-amethyst
multiple-amethystOP3y ago
Ok Solved the problem. The reason is that the x belt pulley is installed reversely Thank you
adverse-sapphire
adverse-sapphire3y ago
np
multiple-amethyst
multiple-amethystOP3y ago
No description
multiple-amethyst
multiple-amethystOP3y ago
It's a little better than before, but it hasn't been completely solved
adverse-sapphire
adverse-sapphire3y ago
What does your tightness graph look like?
multiple-amethyst
multiple-amethystOP3y ago
I have not installed adxl345, not ratos I can also measure using klipper? Here comes the adxl345 I bought. After setting the resonance value
adverse-sapphire
adverse-sapphire3y ago
You can measure with klipper but I'm not sure the procedure. Please do that and post the belt tightness graphs. It's more of an art than a science so we'll try to work on it together.
multiple-amethyst
multiple-amethystOP3y ago
The belt calibration method recommended by another brother has been completely solved. Thank you very much https://www.printables.com/model/151815-belt-tensioner-meter-9-mm-petg-prusament
Printables.com
Belt tensioner meter 9 mm, PETG Prusament by Locki | Download free ...
For 9 mm belts, print from PETG Prusament like original model | Download free 3D printable STL models
multiple-amethyst
multiple-amethystOP3y ago
No description
adverse-sapphire
adverse-sapphire3y ago
Did that fix it?
multiple-amethyst
multiple-amethystOP3y ago
No description
No description
multiple-amethyst
multiple-amethystOP3y ago
It seems to be solved, much better than before
adverse-sapphire
adverse-sapphire3y ago
awesome! Glad I "Helped" lol
multiple-amethyst
multiple-amethystOP3y ago
👍
firm-tan
firm-tan3y ago
How does it works?
multiple-amethyst
multiple-amethystOP3y ago
No description
multiple-amethyst
multiple-amethystOP3y ago
Similar to this, adjust the two belts to the same position in the section
firm-tan
firm-tan3y ago
Do have I to adjusts the belt positioning them in the middle between min and max?
multiple-amethyst
multiple-amethystOP3y ago
Among the suggestions, the worst is not very good Try the effect first. I hope it can help you

Did you find this page helpful?