Z-TILT-ADJUST fails with weird movement
After a slight rebuild of my VCore 3.0 400, I cannot get the Z_TILT_ADJUST to work.
Printer.cfg is attached. Printer homes fine, and I can manually move to all the [points] specified in the [z_tilt] section. As you can see in the video, it moves to the first point fine, but after that some weird stepper sound and it moves off the plate.
Console output as follows:
20:10:22 No trigger on probe after full movement
20:10:14 probe at 60.000,60.000 is z=-0.300938
20:10:09 Z_TILT_ADJUST
Please help. I have not changed my config from when my printer was working fine before. Only had to do some rewiring after a blob-of-death, and also upgraded to the latest EVA
Cheers
6 Replies
[z_tilt] speed: 1500why do you have it at this speed? same for
[bed_mesh] speed: 3000
rare-sapphire•2y ago
I was playing around with speed to observe more carefully what is happening
they seem too high to me, and thus you might be skipping steps because you are trying to accelerate too fast
rare-sapphire•2y ago
Ok will drop them and see quickly
yeah I would remove those speed lines and leave the defaults
rare-sapphire•2y ago
that seem to have done the trick mate, cheers. I am just slightly concerned as to why now all of a sudden. My printer was out of commision for about 2 months, but I only upgraded the carriage and replaced some wires (hotend only). Just wondering why this speed is an issue now? Could it be that my belt tension is not correct?