issues pt1000 rapido 2

Got issues with new rapido 2 plus.. Temp shows hotter than the sun 30mil+ degrees C.. New hotend.. new sensor (but COULD be broken).. also changed the cable from board (octopus 1.1 557) and directly plugged it in.. everything same.. Config: What am i missing here? As its probably a small config thing.. It does fluctuate between 28mil and 30mil degrees
No description
8 Replies
stormy-gold
stormy-gold11mo ago
Nvm, this can be closed.. i get the exact same reading without any thermistor.. thermistor came broken.
blacksmithforlife
thermistors are very simple things, you probably have a bad crimp somewhere
stormy-gold
stormy-gold11mo ago
No... The wires came detached from the actual sensor as they where not properly soldered
stormy-gold
stormy-gold11mo ago
No description
blacksmithforlife
that's unusual, never seen that before!
stormy-gold
stormy-gold11mo ago
Im the 3rd in ratrig with this issue . See hotends section.. its a known issue with a batch of new rapido 2 plus
blacksmithforlife
that sucks, sorry man!
stormy-gold
stormy-gold11mo ago
Dont worry.. i was warned and ordered a spare pt1000 from aliexpress... Hoped i skipped the shit batch.. took a gamble and lost.. downtime of about a week.. no Biggie