need help with bltouch
at first the error was failed to verify sensor state after adding pin up reports not triggered false i get
failed to verify probe is raised the probe is deployed then goes back up and it gives me this error
i already tested the bltouch and it works the probe deploys when testing it(deployed) it says open when touching a piece of paper and triggered when not touching anything
help,thanks
10 Replies
it says open when touching a piece of paper and triggered when not touchingThat's inverted. Given the errors my guess is bad wiring
I did check it but it's wired like the guide says unless the pins on the controller board are inverted I have a octopus v1.1
Should I try and switch the white (z-stop out) and the black(ground)?
@miklschmidt
No i would tripple check that the wiring is correct (as pictured in the wiring diagram), make sure the extension is as well, make sure all the crimps are well done and properly connecting etc etc.
will do, I'll also try a different extension cable
@miklschmidt I check the wiring and it's fine I also tried two different extension cable and I always have the same problem
Right, but alas, your problem is hardware related unless you changed the bltouch pin definitions in your printer.cfg.
I did not, you think the bltouch is faulty?
Not sure. Wait.. Is this an original bltouch or some clone?
@miklschmidt original, I bought the vcore 3.1 kit
Then it makes no sense. You can try inverting the sensor pin
(either add or remove
!
)Man I think I love you, fixed it I added the ! instead of the symbol in the standard config
you are the man
Thanks
I'll try leveling the bed and 3d print
thanks