need help with bltouch

at first the error was failed to verify sensor state after adding pin up reports not triggered false i get failed to verify probe is raised the probe is deployed then goes back up and it gives me this error i already tested the bltouch and it works the probe deploys when testing it(deployed) it says open when touching a piece of paper and triggered when not touching anything help,thanks
10 Replies
miklschmidt
miklschmidt11mo ago
it says open when touching a piece of paper and triggered when not touching
That's inverted. Given the errors my guess is bad wiring
Beluga
Beluga11mo ago
I did check it but it's wired like the guide says unless the pins on the controller board are inverted I have a octopus v1.1 Should I try and switch the white (z-stop out) and the black(ground)? @miklschmidt
miklschmidt
miklschmidt11mo ago
No i would tripple check that the wiring is correct (as pictured in the wiring diagram), make sure the extension is as well, make sure all the crimps are well done and properly connecting etc etc.
Beluga
Beluga11mo ago
will do, I'll also try a different extension cable @miklschmidt I check the wiring and it's fine I also tried two different extension cable and I always have the same problem
miklschmidt
miklschmidt11mo ago
Right, but alas, your problem is hardware related unless you changed the bltouch pin definitions in your printer.cfg.
Beluga
Beluga11mo ago
I did not, you think the bltouch is faulty?
miklschmidt
miklschmidt11mo ago
Not sure. Wait.. Is this an original bltouch or some clone?
Beluga
Beluga11mo ago
@miklschmidt original, I bought the vcore 3.1 kit
miklschmidt
miklschmidt11mo ago
Then it makes no sense. You can try inverting the sensor pin (either add or remove !)
Beluga
Beluga11mo ago
Man I think I love you, fixed it I added the ! instead of the symbol in the standard config you are the man Thanks I'll try leveling the bed and 3d print thanks