Section 'ratos_homing' is not a valid config section

I just wanted to add the EBB32 to my system. And noticed a "corrupt" klipper. After a "Hard recovery" I now get a error saying that my config isn´t correct. Klipper is now on v0.11.0-304-gf7567a0d, while the Octopus V1.1 is on 299. Is this due to 304? If so how can I fix this? TIA, Peter
No description
6 Replies
harsh-harlequin
harsh-harlequin8mo ago
No description
Mietzekatzi
Mietzekatzi8mo ago
I think it has to do with hard resetting klipper.
This happens if you hard reset klipper through mainsail, to relink the extensions go to the configurator at http://ratos.local/configure, click the "Actions" dropdown menu in the top right and pick "Symlink klippy extensions". Then go back to mainsail and restart the klipper service by clicking on the power icon in the top right corner, then the refresh icon next to "Klipper" under "Service controls". You should now be back in action.
See here: https://discord.com/channels/582187371529764864/1118981770533146684/1119013701245218876
firm-tan
firm-tan8mo ago
Thank youu 🙂
harsh-harlequin
harsh-harlequin8mo ago
Seems to work, now the same issue on the ercf section. Will fix this with a reinstall of ercf After the reinstall of ERCF and PAM everything is working again. Halloween is saved.
rare-sapphire
rare-sapphire7mo ago
this worked for me! thank you!!!!
drops
drops5mo ago
This worked. Thank you