LGX Lite first test - TMC 'extruder' reports error
Having a Vcore 3.1 500, I had to extend the wiring from the tool head. Homing XYZ works perfectly as well as the Z tilt. But when I heat up the extruder to over 170C and try the empty extruder i hear a small click followed by this:
TMC 'extruder' reports error: DRV_STATUS: 001600e0 s2vsb=1(ShortToSupply_B!) ola=1(OpenLoad_A!) olb=1(OpenLoad_B!) cs_actual=22 Once the underlying issue is corrected, use the "FIRMWARE_RESTART" command to reset the firmware, reload the config, and restart the host software. Printer is shutdown
I have swapped the drivers. I swapped the X and extruder steppers: - when doing so and cliking extrude, the tool-head moves slowly diagonally. The the board seems to be fine. - when trying to move X or Y with the extruder plugged in X, it crashes to a similar error. I tested the resistance between the 4 extruder wires and get 2.5 Ohm between green and yellow and another 2.5 Ohm between red and blue. No continuity for the different combinations. I checked my custom wiring and I don't seem to have swapped wires accidentally.
Any ideas?
Recent Announcements
Continue the conversation
Join the Discord to ask follow-up questions and connect with the community