VORON IMPLEMENTATION ISSUE - BEACON CALIBRATE
Just completed my 2.4 upgrade to beacon/orbitor2/rapido2UHF to match my RatRigs currently operating. During initial Beacon Calibrate it will not QGL because the values keep increaing like the motors are not assigned correctly. I have looked @ the wiring too many times to count, verified ratos.cfg assignments, verified ratos config wizard selections. Octopus Pro 446, EBB42, PI4b, Kind of at a loss now, any insight????

3 Replies
how does your latency look?
Does the latency get a lot worse once your bed heater is running?
No bed heater on at this point. Starts Beacon Cal, goes directly in to QGL and fails there. Going back through all pulleys and grub screws right now verifying everything there. Z belts all tightened using gage so they are all equal and are reading in the correct zone using a belter. This feels like a mechanical issue.
Okay, dug really deep and really did not need to. I found that my gear ratios were off on the z motor causing the movement to be 1/2 what it should have been leading to crazy numbers. Uncommented the 80:16 line and boom - worked first try. Just another reminder to slow down and think, do not just do without simple root cause analysis.
as I keep getting reminded by my programming mentors, "test your assumptions"