Cant get pass the last vaoc step without movement out of range error or other errors
Please help
1 Reply
I had the 'gcode_macro START_PRINT:gcode': gcode.CommandError: Toolhead x-offset is too high for the available parking space. Calibrate your X and DC endstop positions and make sure you stay below 1mm' error. I eventually discovered that RatOS is very particular about the tool head endstops and their relationship to the VAOC camera. I ended up having to remove about 1mm of plastic from where the T0 endstop switch was triggering and the error went away. I would suggest adding 1mm of tape or something to see if the error goes away before removing the plastic. For me the addition of tape made the error worse. I also noticed that when I fixed the endstop issue, the nozzles were no longer out of the frame when starting the VAOC calibration. Good Luck!