"No Beacon model loaded" after attempting to run "BEACON_INITIAL_CALIBRATION"
Hello all, I am attempting first time commissioning of an IDEX Ratrig Vcore4 500 printer. As mentioned in the title, I run into a snag when attempting to run "BEACON_INITIAL_CALBRATION". I get through homing all axes and print head T0 moves to the center of the plate and then "No Beacon model loaded" is output to the console 5 times.
I've tried some light troubleshooting from the beacon documentation such as listing what models are available (there are none) and trying to generate my own default (unsuccessful).
Does anyone know what I am missing here? I will continue to troubleshoot but I was hoping to find this is a somewhat common and easy issue to resolve. Thanks in advance!
Solution:Jump to solution
I'g going to close this as I ended up finding a solution on my own. My problem ended up being that the beacon probe wasn't fond of one of the usb ports on my raspberry pi. I switched to an open port on the usb waveshare pi hat and that resolved my issues immediately.
1 Reply
Solution
I'g going to close this as I ended up finding a solution on my own. My problem ended up being that the beacon probe wasn't fond of one of the usb ports on my raspberry pi. I switched to an open port on the usb waveshare pi hat and that resolved my issues immediately.