brian
RRCRat Rig Community [Unofficial]
•Created by brian on 4/29/2025 in #ratos-support
temperature_MCU toolhead
I completely understand that the RATOS.cfg shouldn't be edited. The error is "ADC_TEMPERATURE used multiple times in config" because I am trying to add a temperature fan for the toolhead MCU in my printer.cfg, but the toolhead temperature_MCU is already being used for temperature monitoring in RATOS.cfg... Klipper does not like it listed twice, as it is already being used in RATOS.cfg for temperature monitoring. That error is because I list it a 2nd time when trying to use it as a temperature fan reference. Just looking for a workaround, if there is one. Seems the only way would be to just remove the toolhead from RATOS.cfg completely in the configurator and put all the toolhead config in my printer.cfg file.
7 replies